netsec: restore phy power state after controller reset
authorMian Yousaf Kaukab <ykaukab@suse.de>
Thu, 18 Mar 2021 08:50:26 +0000 (09:50 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Tue, 30 Mar 2021 12:31:53 +0000 (14:31 +0200)
commit 804741ac7b9f2fdebe3740cb0579cb8d94d49e60 upstream.

Since commit 8e850f25b581 ("net: socionext: Stop PHY before resetting
netsec") netsec_netdev_init() power downs phy before resetting the
controller. However, the state is not restored once the reset is
complete. As a result it is not possible to bring up network on a
platform with Broadcom BCM5482 phy.

Fix the issue by restoring phy power state after controller reset is
complete.

Fixes: 8e850f25b581 ("net: socionext: Stop PHY before resetting netsec")
Cc: stable@vger.kernel.org
Signed-off-by: Mian Yousaf Kaukab <ykaukab@suse.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/net/ethernet/socionext/netsec.c

index 1503cc9..ef3634d 100644 (file)
@@ -1708,14 +1708,17 @@ static int netsec_netdev_init(struct net_device *ndev)
                goto err1;
 
        /* set phy power down */
-       data = netsec_phy_read(priv->mii_bus, priv->phy_addr, MII_BMCR) |
-               BMCR_PDOWN;
-       netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR, data);
+       data = netsec_phy_read(priv->mii_bus, priv->phy_addr, MII_BMCR);
+       netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR,
+                        data | BMCR_PDOWN);
 
        ret = netsec_reset_hardware(priv, true);
        if (ret)
                goto err2;
 
+       /* Restore phy power state */
+       netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR, data);
+
        spin_lock_init(&priv->desc_ring[NETSEC_RING_TX].lock);