i2c-axxia: check for error conditions first
authorAdamski, Krzysztof (Nokia - PL/Wroclaw) <krzysztof.adamski@nokia.com>
Mon, 10 Dec 2018 15:01:27 +0000 (15:01 +0000)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Tue, 12 Feb 2019 18:47:09 +0000 (19:47 +0100)
commitb5c21b7e31308c4204778268576bc4ca593f72ba
treea9f89c91f876eda4e67c41bfa144fe9cd170eb5f
parentccb7b328361ae6d1cf4e907429381ae37c81520d
i2c-axxia: check for error conditions first

[ Upstream commit 4f5c85fe3a60ace555d09898166af372547f97fc ]

It was observed that when using seqentional mode contrary to the
documentation, the SS bit (which is supposed to only be set if
automatic/sequence command completed normally), is sometimes set
together with NA (NAK in address phase) causing transfer to falsely be
considered successful.

My assumption is that this does not happen during manual mode since the
controller is stopping its work the moment it sets NA/ND bit in status
register. This is not the case in Automatic/Sequentional mode where it
is still working to send STOP condition and the actual status we get
depends on the time when the ISR is run.

This patch changes the order of checking status bits in ISR - error
conditions are checked first and only if none of them occurred, the
transfer may be considered successful. This is required to introduce
using of sequentional mode in next patch.

Signed-off-by: Krzysztof Adamski <krzysztof.adamski@nokia.com>
Reviewed-by: Alexander Sverdlin <alexander.sverdlin@nokia.com>
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/i2c/busses/i2c-axxia.c