clk: tegra: Fix duplicated SE clock entry
authorDmitry Osipenko <digetx@gmail.com>
Sun, 25 Oct 2020 22:42:12 +0000 (01:42 +0300)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 30 Dec 2020 10:53:49 +0000 (11:53 +0100)
commit0440989a08a5c71a7304da3dcb7d43de968cb721
treea54d03a5b287bcbbeb3d9d34eafc15cfb927492b
parentbe5c560996ac9ed1e3f3f1e03c8c090f39a71e8a
clk: tegra: Fix duplicated SE clock entry

[ Upstream commit 5bf5861d6ea6c3f4b38fc8fda2062b2dc44ac63d ]

The periph_clks[] array contains duplicated entry for Security Engine
clock which was meant to be defined for T210, but it wasn't added
properly. This patch corrects the T210 SE entry and fixes the following
error message on T114/T124: "Tegra clk 127: register failed with -17".

Fixes: dc37fec48314 ("clk: tegra: periph: Add new periph clks and muxes for Tegra210")
Tested-by Nicolas Chauvet <kwizart@gmail.com>
Reported-by Nicolas Chauvet <kwizart@gmail.com>
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Link: https://lore.kernel.org/r/20201025224212.7790-1-digetx@gmail.com
Acked-by: Thierry Reding <treding@nvidia.com>
Signed-off-by: Stephen Boyd <sboyd@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/clk/tegra/clk-id.h
drivers/clk/tegra/clk-tegra-periph.c